Measuring Dynamic Motor Characteristics

Record inverter output voltage and current, torque, and RPM from motor start to stop.
Calculate inver ter output power, motor power, and motor efficiency using waveform calculations.

Measurement Example

Calculate Inverter Output Power, Motor Power, and Motor Efficiency Using Waveform Calculations

Calculate motor power, motor efficiency, and inverter output power after measurement using high-speed waveform calculations and display the results using the instrument's X-Y display function. The ability to use the X-Y display for waveform calculation results as well as input signals from measurement units means you can perform a broad range of analyses. Additionally, X-Y analysis can be performed at user-specified areas of the recorded fluctuating waveform, since you can choose waveform areas for generating an X-Y display.

Equipment Used

MEMORY HiCORDER MR6000/MR6000-01

MEMORY HiCORDERMR6000/MR6000-01

4CH ANALOG UNIT U8978

4CH ANALOG UNITU8978

3CH CURRENT UNIT U8977

3CH CURRENT UNITU8977

FREQ UNIT 8970

FREQ UNIT8970

STRAIN UNIT U8969

STRAIN UNITU8969

DIFFERENTIAL PROBE 9322

DIFFERENTIAL PROBE9322

AC/DC CURRENT PROBE CT6843-05

AC/DC CURRENT PROBECT6841-05

CONNECTION CORD L9197

CONNECTION CORDL9197

Torque sensor(strain gage-type converter)

(For more information about the sensor, please contact the sensor manufacturer.)

Download the catalog summarizing the applications of this site or get in contact with HIOKI in your country.